<img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=354329995582546&amp;ev=PageView&amp;noscript=1">

CLEANSE® | RETROFIT TROFFER

Utilizes a combination of air filtration with UV (A+C) light to sanitize air, inactivate pathogens, and decrease contamination while providing comfortable healthy light to illuminate the work space.

Information

  • Description
  • Key Features
  • Technical Information
  • Financial expenditure
  • Servicing Requirements

Cleanse® Air-Purifier Retrofit Troffer utilizes a combination of air filtration with UV (A+C) light to sanitize air, inactivate pathogens, and decrease contamination while providing comfortable healthy LED light to illuminate the work space. Easily retrofit any existing standard 2 ft x 4 ft light fitting in a suspended ceiling grid, in as little as 15 minutes to the air-sanitizing Cleanse Retrofit Troffer- without breaching the plenum keeping facility disruptions and installation cost at a minimum.

Easily retrofit of any existing standard 610 x 1220mm luminaire to an air sanitizing LED luminaire with the Cleanse Retrofit Troffer in as little as 15 minutes- without breaching the plenum, keeping facility disruptions and installation cost at a minimum.

Ultra efficient multi-stage air sanitization process that utilizes easy to replace HEPA/ charcoal filter and UV LED (A+C) module. Recommended to replace filter every 6 months and UV LED module every 6-12 months.

Achieves 99.9% removal rate among four common airborne pathogens responsible for most hospital acquired infections.

Three function modes controlled by manual or Bluetooth; Illumination Mode + Air Cleaning Normal Mode; Illumination Mode only (100% light output) or Air Cleaning Normal Mode Only

UV LED have four times the life expectancy without the safety concerns of hazardous material exposure or waste disposal in comparison to traditional mercury based bulbs.

Troffer provides 22cubic metres of sanitizing coverage and conducts four air changes per hour (50cfm) for a 3m x 3m x2.4m space.

Features Healthe’s patented True Circadian spectrum technology with a choice of GoodDay (5000K or 4000K) suitable for daytime intensive environments or GoodNight (2700K) ideal for evening applications.

Recessed Housing Kit (ACC-07010) can be purchased separately for installation due to incompatibility with existing troffer housing or in new construction settings.
 
ILLUMINATION
 
Correlated Color Temperature (CCT): GoodDay 5000K, 4000K, GoodNight 2700K, Standard White 3000K
Lumen Output: 3200 lm (Max.)
Color Rendering Index: 90 GoodDay 5000K, 4000K, Std 3000K, 80 GoodNight 2700K
Light Distribution: Lambertian
 
 
AIR SANITIZATION
 
Filtration: HEPA-Carbon Activated Filter captures up to 99.97% of particles as small as 0.3µ
Air Flow Rate: 50 CFM/23CMM (Max.)
UV Sanitization: UV LED (A+C) Activated Photo-Catalytic Purification Process
UV LED Lifetime to L50:  >2,000 Hours
 
 
ELECTRICAL
 
Power Consumption:
60 Watts @ Illumination Mode + Air Cleaning Normal Mode
36 Watts @ Illumination Mode only (100% light output)
24 Watts @ Air Cleaning Normal Mode Only
Input Voltage: 120–277 VAC
Frequency: 50/60Hz
Input AC Current (Max.): 0.95–0.4A
Control Protocol: Proprietary Bluetooth
Control 2 Options: Standard Wall Switch or Wireless Control Devices
Dimming Range: 5% to 100% via proprietary Bluetooth
Fan Speed Control: Speed controlled via proprietary Bluetooth
 
 
MECHANICAL
 
Housing: Sheet Metal
Dimensions: 610 x 1220 x 73mm (W x L x H)
Weight: 15.5kg
Finish: Powder-Coated White
Mounting:  Retrofit to Standard 2’ x 4’ Troffer Housing. A compatible Recessed Housing Kit (code: ACC-07010) available, sold separately
 
INSTALLATION
 
The primary goal in installing the Cleanse Toffer is air sanitization and the secondary benefit, general illumination. Any spacing criteria should therefore be dictated by the sanitization needs.
A single troffer is recommended in a 10ftx10ftx8ft room, where at maximum fan speed (50cfm) it will pull approximately 4 air changes per hour.
Using these volumetric guidelines for larger, open spaces or lobbies, Cleanse Troffers should be installed on 8-10ft centres for maximum sanitization. With retrofit applicaitons, this spacing and quantity may not always be feasible, so selective placement in high traffic or vulnerable locations such as waiting rooms is recommended.

Perfect for all SME and large commercial operations, offices, hospitality, hotel, education sector and healthcare. Quick and easy to retrofit into standard suspended ceiling grid. Reduction of airborne pathogens reduces sick and leave days taken by staff and students therefore decreasing staffing costs; particularly during the winter months. 

For optimal sanitization performance, Healthe recommends replacing carbon/HEPA filter every 6 months and UV LED recommended every 6 to 12 months depending on usage 

ACCESSORIES ORDERING

Part Number/ Product Description
ACC-07010: 2x4 Recessed Housing
ACC-07006: HEPA/Charcoal Filter Replacement (Recommended every 6 months)
ACC-07003: UV(A+C) LED Module Replacement (Recommended 6 to 12 months depending on usage*)

To order replacement accessories, please contact PBI Ultra on 03 357 0093
idea

HAVE A QUESTION?

LET'S CHAT UVC DISINFECTION - IT'S WHAT WE DO!

Contact Us

Whether you're working on a new project, looking to retrofit to an existing building, or after mobile sanitization, we would love to help. Get in touch by any means and our UV experts will see you right.